Related Experiment Video
Updated: Jul 16, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Automated measurement of blood pressure in routine clinical practice
Martin G Myers1, Marshall Godwin
1Shulech Heart Centre, Sunnybrook Health Sciences Centre and the Department of Medicine, University of Toronto, Ontario, Canada. martin.myers@sunnybrook.ca
Abstract:
In recent years, automated devices have been developed to record blood pressure (BP) accurately in the home and during usual daily activities. Clinical outcome studies have clearly shown home BP and 24-hour ambulatory BP to be significantly better predictors of future cardiovascular events compared with BP recorded in the office setting using mercury sphygmomanometry. It is also now possible to measure office BP with the patient resting quietly alone in the examining room using an automated device. Studies in routine clinical practice using this approach have demonstrated that automated office BP can eliminate most of the white coat effect seen with manual BP measurement. The automated office BP also correlates significantly better than does the routine office BP with the 24-hour ambulatory BP, the gold standard for predicting risk of future cardiovascular events. Sufficient evidence now exists to consider incorporating automated office BP into an algorithm for diagnosing hypertension.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.