Related Experiment Video
Updated: Jul 15, 2026

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Localizing circuits of atrial macroreentry using electrocardiographic planes of coherent atrial activation
Andrew M Kahn1, David E Krummen, Gregory K Feld
1University of California and Veterans Affairs Medical Centers, San Diego, California 92161, USA.
Background:
The complexity of ablation for atrial macroreentry atrial flutter (AFL) varies significantly depending on the circuit location. Presently, surface electrocardiogram (ECG) analysis poorly separates left from right atypical AFL and from some cases of typical AFL, which delays diagnosis until invasive study.
Objective:
The purpose of this study was to differentiate and localize the intra-atrial circuits of left atypical AFL, right atypical, and typical AFL using quantitative ECG analysis.
Methods:
We studied 66 patients (54 men, age 59 +/- 14 years) with typical (n = 35), reverse typical (n = 4), and atypical (n = 27) AFL. For each, we generated filtered atrial waveforms from ECG leads V5 (X-axis), aVF (Y-axis), and V1 (Z-axis) by correlating a 120-ms F-wave sample to successive ECG regions. Atrial spatial loops were plotted for three orthogonal planes (frontal, XY = V5/aVF; sagittal, YZ = aVF/V1; axial, XZ = V5/V1) and then cross-correlated to measure spatial regularity (i.e., coherence; range -1 to 1).
Results:
Mean coherence was greatest in the XY plane (P <10(-3) vs. XZ or YZ). Atypical AFL showed lower coherence than typical AFL in the XY (P <10(-3)), YZ (P <10(-6)), and XZ (P <10(-5)) planes. Atypical left AFL could be separated from atypical right AFL by lower XY coherence (P = .02); for this plane, coherence <0.69 detected atypical left AFL with 84% specificity and 75% sensitivity. F-wave amplitude alone did not separate typical, atypical right, or atypical left AFL (P = NS).
Conclusions:
Atypical AFL shows lower spatial coherence than typical AFL, particularly in the sagittal and axial planes. Coherence in the Cartesian frontal plane separated left and right atypical AFL. Such analyses may be used to plan ablation strategy from the bedside.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
08:19Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...