Related Experiment Video
Updated: Jul 15, 2026

RNAscope for In situ Detection of Transcriptionally Active Human Papillomavirus in Head and Neck Squamous Cell Carcinoma
Published on: March 11, 2014
Absolute quantitative real-time polymerase chain reaction for the measurement of human papillomavirus E7 mRNA in
Michael E Scheurer1, Laura M Dillon, Zhuo Chen
1The University of Texas M. D. Anderson Cancer Center, Department of Epidemiology, Unit 1340, PO Box 301439, Houston, TX 77230-1439, USA. mescheur@mdanderson.org
Background:
Few reports of the utilization of an accurate, cost-effective means for measuring HPV oncogene transcripts have been published. Several papers have reported the use of relative quantitation or more expensive Taqman methods. Here, we report a method of absolute quantitative real-time PCR utilizing SYBR-green fluorescence for the measurement of HPV E7 expression in cervical cytobrush specimens.
Results:
The construction of a standard curve based on the serial dilution of an E7-containing plasmid was the key for being able to accurately compare measurements between cervical samples. The assay was highly reproducible with an overall coefficient of variation of 10.4%.
Conclusion:
The use of highly reproducible and accurate SYBR-based real-time polymerase chain reaction (PCR) assays instead of performing Taqman-type assays allows low-cost, high-throughput analysis of viral mRNA expression. The development of such assays will help in refining the current screening programs for HPV-related carcinomas.