Noncontact measurement of electrostatic fields: verification of modeled potentials within ion mobility spectrometer

Jill R Scott1, Paul L Tremblay

  • 1Idaho National Laboratory (INL), Idaho Falls, ID 83415-0001, USA. jill.scott@inl.gov

Related Concept Videos

Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
Electrochemical Systems01:24

Electrochemical Systems

Electrochemical systems provide a fascinating insight into the dynamic interplay of charged species within various phases. One notable example is the interaction between a membrane permeable to K⁺ ions but not to Cl⁻ ions, separating an aqueous KCl solution from pure water. As K⁺ ions diffuse through the membrane, they generate net charges on each phase, leading to a potential difference between them.Similarly, when a piece of Zn is immersed in an aqueous ZnSO₄ solution, the Zn metal, composed...
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...