Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Exeter total hip arthroplasty with matte or polished stems
Alfredas Smailys1, Sarūnas Tarasevicius, Uldis Kesteris
1Department of Orthopedics and Traumatology, Kaunas University of Medicine, Eiveniu 2, Kaunas, Lithuania. smailys@takas.lt
Medicina (Kaunas, Lithuania)
|April 7, 2007
Summary
Total hip arthroplasty implant survival rates did not differ between Exeter matte and polished stems. However, increased capsular distension was significantly related to cup loosening in hip replacement patients.
Area of Science:
- Orthopedic Surgery
- Biomaterials Science
- Medical Imaging
Background:
- Total hip arthroplasty (THA) is a common procedure to address hip joint degeneration.
- The choice of femoral stem design, specifically surface finish (matte vs. polished), may influence long-term implant performance.
- Synovitis and joint effusion can be indicators of complications such as implant loosening.
Purpose of the Study:
- To compare implant survival rates between Exeter matte and polished stems in primary total hip arthroplasty.
- To investigate the association between synovitis/joint effusion and signs of implant loosening, considering stem type.
Main Methods:
- Retrospective analysis of revision rates for 118 primary hip replacements using Exeter matte (n=47) or polished (n=71) stems.
- Prospective evaluation of 24 patients (11 polished, 13 matte) using radiography and sonography to assess capsular distension.
- Sonography measured the distance between the femoral neck and anterior capsule to quantify capsular distension, indicative of synovitis.
Main Results:
- Implant survival at 13 years postoperatively was 78% for matte stems and 61% for polished stems (P=0.27).
- Stem survival rates were 82% for matte and 88% for polished stems (P=0.54).
- A significant relationship was found between increased capsular distension and cup loosening (P=0.04), but no significant difference in capsular distension was observed between matte and polished stems.
Conclusions:
- There was no statistically significant difference in overall implant survival rates between Exeter matte and polished stems.
- Increased capsular distension, a sonographic marker for synovitis, is significantly associated with cup loosening in total hip arthroplasty.
- Stem surface type did not significantly impact capsular distension.