Corneal oxygen uptake associated with piggyback contact lens systems
Lindsay N Florkey1, Barbara A Fink, G Lynn Mitchell
1The Ohio State University College of Optometry, 320 West Tenth Avenue, Columbus, OH 43210-1280, USA.
Purpose:
The purpose of this study was to determine the effects of static (without blinking) and dynamic (with blinking once every 5 seconds) wear of piggyback contact lens systems on corneal oxygen uptake.
Methods:
Corneal oxygen uptake rates were measured on the right eyes of 11 human subjects by using a polarographic electrode. Measurements were made for the normal open eye and after 5 minutes of wear of 4 rigid lens materials (Dk/t 0-82.5), 4 soft lens materials (Dk/t 13-122), and 16 combinations of rigid and soft lens materials. The piggyback systems were worn under both static and dynamic conditions. Repeated-measures analysis of variance was used to compare oxygen uptake rates associated with the wear of the rigid lens components, soft lens components, piggyback systems, and static versus dynamic wearing conditions. Spearman correlation coefficients and regression analyses were used to examine relationships between corneal oxygen uptake rates.
Results:
Measurable differences were found among oxygen uptake rates associated with the rigid lens components, soft lens components, and piggyback systems. Blinking resulted in no reduction in corneal oxygen uptake with the piggyback systems. Corneal oxygen uptake associated with the wear of the piggyback systems could not be predicted from those associated with the rigid and soft lens components of the systems.
Conclusions:
Piggyback combinations of rigid and soft lens components with the highest transmissibilities resulted in the least increase in corneal oxygen uptake beyond that of the normal open eye.
Related Concept Videos
Ophthalmic Drug Delivery Systems
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...