[Usefulness of a glaucoma and ocular hypertension screening strategy in primary care]
Francisca García de Blas González1, Miguel Angel Barajas Gutiérrez, Pedro Beneyto Martín
1Medicina Familiar y Comunitaria Equipo de Atención Primaria Dr Mendiguchía Carriche, Leganés, Servicio Madrileño de Salud, Area 9, Madrid, Spain. fgarciadeblas@medynet.com
Objectives:
To evaluate the usefulness of a glaucoma and intraocular hypertension screening strategy for new cases detected. To evaluate the acceptability of taking intra-ocular pressure (IOP) and the appearance of side effects.
Design:
Cross-sectional, descriptive study.
Setting:
An urban health centre and the ophthalmology clinic of its main hospital.
Participants:
A total of 2044 patients aged over 40, 63.5% women and 36.5% men, with a mean age of 61.23 (SD, 11.42). They were selected by consecutive sampling from patients who visited the health centre over a 9-month period. Subjects diagnosed with glaucoma, ocular hypertension (OH), conjunctivitis, or corneal pathology were excluded.
Interventions:
Taking of IOP with Tonopen XL in primary care. Subjects with IOP > or = 21 mm Hg were referred to ophthalmology. In these patients, IOP was measured with Goldmann, and patients with confirmed OH received ophthalmoscopy and campimetry.
Main Measurements:
Percentage of subjects with glaucoma, suspected glaucoma, and OH confirmed in ophthalmology. Positive predictive value (PPV) for OH.
Results:
One hundred subjects with OH were detected (4.89%; 95% CI, 3.93%-5.85%), of whom 21 were diagnosed with glaucoma (1.04%; 95% CI, 0.57-1.49) and 10 with suspected glaucoma (0.49%; 95% CI, 0.16-0.82). The PPV for OH was 44.27%. The acceptability of the test was 98.09%. No patients presented with side-effects following the taking of their IOP.
Conclusions:
The strategy evaluated is useful in terms of the number of subjects with glaucoma and OH detected. The acceptability of taking IOP with Tonopen XL was high.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Ophthalmic Drug Delivery Systems
Errors occurring during blood pressure monitoring
Several factors...
Hypertension III: Clinical Manifestations and Diagnostic Studies