Related Experiment Video
Updated: Jul 15, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Assessment of the multimedia mitigation of radon in New York
1Wadsworth Center, New York State Department of Health, PO Box 509, Albany, NY 12201, USA. kitto@wadsworth.org
Abstract:
Although not yet implemented, the 1996 amendments to the Safe Drinking Water Act instructed the states (or local water suppliers) to address radon concentrations in community water systems (CWS). As an alternative to reducing waterborne radon concentrations in the CWS to the maximum contaminant level (MCL) of 11 Bq L(-1), states (or individual CWS) would be permitted to develop a multimedia mitigation (MMM) program, which allowed a greater concentration (148 Bq L(-1)) of waterborne radon in the CWS, if it could be shown that an equivalent health risk reduction could be achieved by reducing indoor radon concentrations. For a MMM program to be acceptable, the U.S. Environmental Protection Agency required the health-risk reduction attained through mitigations and radon-resistant new construction (RRNC) to offset the increased health risk due to radon in community water systems above the MCL of 11 Bq L(-1). A quantitative assessment indicates that the reduction in health risk currently achieved in New York State through radon mitigations and RRNC exceeded the increase in risk associated with an alternative MCL of 148 Bq L(-1). The implementation of a MMM program in New York would result in an overall reduction in the health risk associated with exposure to radon.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:06Efficient Method for Imaging Murine Lungs that Preserves Spatial Dynamics of Fungal Spores in the Airways
Published on: December 13, 2024
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force per...
Microbial Bioremediation of Uranium
Radiation: Applications
The average...