Related Experiment Video
Updated: Jul 15, 2026

Studying Microbial Communities In Vivo: A Model of Host-mediated Interaction Between Candida Albicans and Pseudomonas Aeruginosa in the Airways
Published on: January 13, 2016
Patterns and dynamics of airway colonisation in mechanically-ventilated patients
J-E Berdal1, J Bjørnholt, A Blomfeldt
1Medical Department, Akershus University Hospital, University of Oslo, Nordbyhagen, Norway. jan.erik.beral@ahus.no
Abstract:
The aim of this study was to investigate the patterns and dynamics of the microbiota in the airways of ventilated patients. Seventy-four mechanically-ventilated patients were recruited consecutively, and oropharyngeal, tracheal and bronchoalveolar (BAL) fluid specimens were collected 48 h after intubation, and every 72 h thereafter until the patient was extubated or a total of five sample sets had been collected. Ventilator-associated pneumonia (VAP) pathogens were identified, quantified and genotyped. Microbial findings were highly correlated both between airway locations and over time when samples were taken no more than 72 h apart. If no VAP pathogen was present in the oral flora, it was unlikely to be found in a lower airway sample; i.e., the positive predictive value of the oropharyngeal sample was 0.73 (95% CI 0.67-0.80), and the negative predictive value was 0.95 (95% CI 0.92-0.99). Colonisation with Enterobacteriacae, non-fermentative bacteria and Staphylococcus aureus was monoclonal in the airways and over time, whereas colonisation with microbes normally found in the oropharynx, i.e., Haemophilus influenzae, Haemophilus parainfluenzae and Streptococcus pneumoniae, was polyclonal. When antibiotics were used, the chance of recovering VAP pathogens from all sampling sites was reduced three-fold. No correlation was observed between a bacterial count of > or =10(4) CFU/mL in BAL fluid and chest X-rays compatible with VAP.
Related Concept Videos
Microbiota of the Respiratory Tract
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pneumonia II: Pathophysiology
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pneumothorax II: Pathophysiology
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: