Corneal refractive therapy with different lens materials, part 2: effect of oxygen transmissibility on corneal shape
Fenghe Lu1, Trefford Simpson, Luigina Sorbara
1Centre for Contact Lens Research, School of Optometry, University of Waterloo, Canada [corrected]
Purpose:
To compare the effects of two different oxygen transmissible (Dk/t) lenses on corneal shape and optical performance after one night of corneal refractive therapy (CRT(R)) for myopia.
Methods:
Twenty myopic subjects were fit with Menicon Z (MZ) (Dk/t = 90.6, Paragon CRT(R) lenses) on one eye and an Equalens II (EII) CRT lens (Dk/t = 47.2) on the contralateral eye (eye randomized). Corneal topography, refractive error and aberrations were measured before lens insertion (baseline), and the following day after overnight lens wear, on lens removal and 1, 3, 6, 12 h later. Root mean square wavefront errors were measured using 4.5 mm pupils.
Results:
Averaged over position and time, the horizontal corneal curvature was statistically different between the MZ and EII lens-wearing eyes (p = 0.011). The central cornea flattened similarly (p = 0.886) and the mid-periphery steepened in both eyes (p = 0.061) from baseline. The EII lens-wearing eyes were steeper in the mid-periphery than the MZ eyes immediately after lens removal and at the 1-h visit (p < or = 0.032). Central corneal flattening and mid-peripheral corneal steepening regressed over time (all p < 0.001) but did not recover to baseline by 12 h (all p < 0.004). Myopia was reduced equally by 0.84 +/- 0.83 D for the MZ-lens wearing eyes and 0.84 +/- 0.87 D for the EII eyes (p = 0.969). Coma increased from baseline 1.85X (0.056 +/- 0.081 microm) for the MZ-lens wearing eyes and 1.72X (0.048 +/- 0.084 microm) for the EII eyes (both p < 0.001). Spherical aberration increased from baseline 4.55X (0.101 +/- 0.077 microm) for the MZ-lens wearing eyes and 4.31X (0.085 +/- 0.076 microm) for the EII eyes (both p < 0.001), but there were no differences between the MZ and EII eyes (all p > or = 0.308). Coma and spherical aberration did not return to baseline by 12 h (both p < or = 0.007).
Conclusions:
After one night of CRT lens wear, changes in corneal shape were slightly different, with more mid-peripheral steepening in the EII eyes compared to the MZ eyes. Change in central corneal curvature and optical performance were similar in both eyes.
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Ophthalmic Drug Delivery Systems
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...