Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Initial Clinical Experience with [<sup>177</sup>Lu]Lu-RTX-2358 Radiopharmaceutical Therapy Targeting Fibroblast Activation Protein: Biodistribution, Pharmacokinetics, and Dosimetry.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine·2026
Same author

Analytical methods for system matrix calculation and spatial resolution evaluation of DC-SPECT system.

Physics in medicine and biology·2025
Same author

Biodistribution and Radiation Dosimetry for [<sup>68</sup>Ga]Ga-LNTH-1363S, a Probe Targeting Fibroblast Activation Protein α.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine·2025
Same author

Examination of aperture layout designs for an adaptive-stationary multi-pinhole brain-dedicated SPECT system.

Medical physics·2025
Same author

Correction of multiplexing artefacts in multi-pinhole SPECT through temporal shuttering, de-multiplexing of projections, and alternating reconstruction.

Physics in medicine and biology·2024
Same author

Characterization, Bioactivity, and Biodistribution of 35 kDa Hyaluronan Fragment.

Life (Basel, Switzerland)·2024

Related Experiment Video

Updated: Jul 15, 2026

Multianimal Magnetic Resonance Imaging for Tumor Measurements in Pancreatic Cancer Mouse Models
09:18

Multianimal Magnetic Resonance Imaging for Tumor Measurements in Pancreatic Cancer Mouse Models

Published on: February 3, 2026

The multi-module, multi-resolution system (M3R): a novel small-animal SPECT system.

Jacob Y Hesterman1, Matthew A Kupinski, Lars R Furenlid

  • 1College of Optical Sciences, University of Arizona, 1630 E. University Blvd., Tucson, Arizona 85721, USA.

Medical Physics
|April 19, 2007
PubMed
Summary

We developed an affordable, high-resolution tomographic imaging system (M3R) with interchangeable components for versatile magnification and pinhole configurations. This flexible design allows optimization for various imaging tasks and future upgrades, enhancing sensitivity and performance.

More Related Videos

Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging
10:17

Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging

Published on: June 26, 2017

Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse
12:24

Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse

Published on: June 20, 2014

Related Experiment Videos

Last Updated: Jul 15, 2026

Multianimal Magnetic Resonance Imaging for Tumor Measurements in Pancreatic Cancer Mouse Models
09:18

Multianimal Magnetic Resonance Imaging for Tumor Measurements in Pancreatic Cancer Mouse Models

Published on: February 3, 2026

Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging
10:17

Switchable Acoustic and Optical Resolution Photoacoustic Microscopy for In Vivo Small-animal Blood Vasculature Imaging

Published on: June 26, 2017

Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse
12:24

Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse

Published on: June 20, 2014

Area of Science:

  • Medical Imaging
  • Instrumentation
  • Physics

Background:

  • Tomographic imaging systems are crucial for detailed anatomical and functional visualization.
  • Existing systems may lack flexibility in magnification and aperture configuration, limiting adaptability.
  • The need for cost-effective, high-resolution imaging solutions persists across various scientific domains.

Purpose of the Study:

  • To introduce the multi-module, multi-resolution (M3R) system, an inexpensive, high-resolution tomographic imager.
  • To detail the design, construction, and calibration of the M3R system.
  • To highlight the system's flexibility for diverse imaging applications and future enhancements.

Main Methods:

  • Designed and constructed an adaptable tomographic imaging system with interchangeable pinhole plates.
  • Incorporated modularity to allow for a wide range of magnifications and pinhole configurations.
  • Developed calibration methods and reconstruction algorithms for image processing.

Main Results:

  • The M3R system offers high resolution and adaptability through its modular design.
  • Interchangeable pinhole plates enable precise control over magnification and aperture.
  • Demonstrated the system's capability for optimization and future upgrades.

Conclusions:

  • The M3R system provides a cost-effective and flexible solution for high-resolution tomographic imaging.
  • Its adaptable design facilitates optimization for specific imaging tasks and integration of new technologies.
  • The M3R system represents a significant advancement in accessible tomographic imaging technology.