Related Experiment Video
Updated: Jul 15, 2026

Using Continuous Data Tracking Technology to Study Exercise Adherence in Pulmonary Rehabilitation
Published on: November 8, 2013
Validity of four indirect methods to measure adherence in primary care hypertensives
1Department of Public Health, Centre for Health Sciences, Federal University at Santa Catarina, Campus Universitário, Trindade, Florianópolis, Santa Catarina, Brazil. jcpradojr@gmail.com
Abstract:
High blood pressure (HBP) is one of the most important risk factors for morbidity and mortality in the world. Non-adherence to medication is associated with the lack of control of HBP. The objective of this study was to assess the validity of four indirect methods for measuring adherence to medication to control HBP in primary health care. A random sample of 120 hypertensive patients who were undergoing treatment for at least 2 months in a primary care unit in Florianópolis (Brazil) were included in the study. The independent variables were four indirect methods to measure adherence to medication: knowledge regarding the HBP medication, the blood pressure level, attitude regarding the medication intake (Morisky-Green test) and self-reported adherence. The classification of HBP was based on criteria established by the Brazilian Ministry of Health. The gold standard used for measuring adherence was the pill count. Logistic regression was used to estimate sensitivity (highest value of 88.2% for self-report), specificity (highest value of 70.7% for HBP control), positive predictive value (highest value of 46.4% for HBP control) and negative predictive value (highest value of 79.1% for Morisky-Green test) for each of the indirect methods. No indirect method of measuring adherence had a good positive predictive value for adherence, which was best predicted by patients' age and whether they managed to control HBP. The results also revealed low treatment adherence (31.2%) and low control of HBP (37.6%). Non-adherence was mainly associated with side effects of the treatment.
Related Concept Videos
Hypertension III: Clinical Manifestations and Diagnostic Studies
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...