Related Experiment Video
Updated: Jul 15, 2026

Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015
Image reconstruction in optical tomography in the presence of coupling errors
Martin Schweiger1, Ilkka Nissilä, David A Boas
1Centre for Medical Image Computing, University College London, London, UK. M.Schweiger@cs.ucl.ac.uk
Abstract:
Image reconstruction in optical tomography is a nonlinear and generally ill- posed inverse problem. Noise in the measured surface data can give rise to substantial artifacts in the recovered volume images of optical coefficients. Apart from random shot noise caused by the limited number of photons detected at the measurement site, another class of systematic noise is associated with losses specific to individual source and detector locations. A common cause for such losses in data acquisition systems based on fiber-optic light delivery is the imperfect coupling between the fiber tips and the skin of the patient because of air gaps or surface moisture. Thus the term coupling errors was coined for this type of data noise. However, source and detector specific errors can also occur in noncontact measurement systems not using fiber-optic delivery, for example, owing to local skin pigmentation, hair and hair follicles, or instrumentation calibration errors. Often it is not possible to quantify coupling effects in a way that allows us to remove them from the data or incorporate them into the light transport model. We present an alternative method of eliminating coupling errors by regarding the complex-valued coupling factors for each source and detector as unknowns in the reconstruction process and recovering them simultaneously with the images of absorption and scattering. Our method takes into account the possibility that coupling effects have an influence on both the amplitude and the phase shift of the measurements. Reconstructions from simulated and experimental phantom data are presented, which show that including the coupling coefficients in the reconstruction greatly improves the recovery of absorption and scattering images.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

