Improving Infrared Spectroscopy Characterization of Soil Organic Matter with Spectral Subtractions
Published on: January 10, 2019
Autocorrelation infrared analysis of mineralogical samples: the influence of user controllable experimental
Adam J Blanch1, Jamie S Quinton, Claire E Lenehan
1Nanostructures & Molecular Interactions Research Group, School of Chemistry, Physics and Earth Sciences, Flinders University, Adelaide, South Australia, Australia.
Abstract:
Autocorrelation infrared (ACIR) analysis is based upon the application of the autocorrelation function corr(alpha,omega') = integral(-infinity)(infinity) alpha(omega + omega') alpha(omega) d omega to standard Fourier transform infrared (FTIR) transmission spectra. We present a rigorous examination of the effect of experimental parameters such as dilution ratio, spectral resolution, grinding time and pressing conditions upon the ACIR analysis of haematite. Results were found to vary by less than 4.5% irrespective of sample preparation, instrumental and data collection parameters. For a series of perovskite samples, the relationship between the measured effective linewidth and material composition appears to be reproducible, even though the absolute magnitudes of delta corr values do not. Our results further indicate that the ACIR technique is indeed valid for comparative analysis of synthetic sample sequences that vary slightly in composition or structural state, provided that primary spectra are all recorded by the same instrument.
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
IR Spectrometers
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...