Related Experiment Video
Updated: Jul 15, 2026

A Test Bed to Examine Helmet Fit and Retention and Biomechanical Measures of Head and Neck Injury in Simulated Impact
Published on: September 21, 2017
Multidetector computed tomography imaging of facial trauma in accidental falls from heights
E M Salonen1, M P Koivikko, S K Koskinen
1Helsinki Medical Imaging Center, Department of Radiology, Töölö Trauma Center, Helsinki University Hospital, Helsinki, Finland. elina.m.salonen@hus.fi
Purpose:
To assess multidetector computed tomography (MDCT) findings in facial trauma in adults who accidentally fall from heights.
Material And Methods:
Of the MDCT scans of 2413 cases requested by emergency-room physicians for suspected facial injury, 155 (age 15.3-76.7, mean 42.0 years; 134 male, 21 female) met the criteria of falling from heights. These were reviewed by two researchers by consensus.
Results:
Of these 155, 118 (104 male, 14 female) had 247 fractures, while 37 had no fracture. The fractures were classified into 13 categories, the zygomatic complex being the region most frequently involved. Mean falling height, known in 132 of 155 cases, was 5.7 m (range 0.4-25) in all, 6.0 m (0.4-25) in those suffering a fracture, and 5.0 m (range 0.4-13) in those without a fracture. Patients with Le Fort II, Le Fort III, or frontal bone fractures had fallen higher and frequently had associated skull base fractures, but with considerable overlap in falling heights. Zygomatic arch and nasal bone fractures rarely occurred solitarily.
Conclusion:
In a fall-from-height injury, nasal bone and zygomatic arch fractures indicate the presence of more severe fractures. Height cannot solely predict injury probability. Clear sinus sign is a valuable aid in assessing midface trauma in falls from heights.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
08:27Development of an Uncomplicated Mild Traumatic Brain Injury Model Modified by Weight-Drop Method and Evidenced by Magnetic Resonance Imaging
Published on: April 11, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...