Related Experiment Video
Updated: Jul 15, 2026

Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
Sensitivity and specificity of a reagent-impregnated test strip in identifying smokeless tobacco users
Elbert D Glover1, Penny N Glover, Molly T Laflin
1Department of Public and Community Health, College of Health and Human Performance, University of Maryland, College Park, MD 20742, USA. eglover1@umd.edu
Abstract:
This study was designed to determine the sensitivity and specificity of a reagent-impregnated test strip in identifying habitual snuff users and tobacco chewers. Urine specimens were obtained from smokeless tobacco users and controls and blind tested on-site using a reagent-impregnated test strip. Samples also were sent to our university hospital lab for cotinine and nicotine analysis by gas chromatography (GC). The test strip results were compared with GC results and self-reported use of snuff and chewing tobacco. A total of 61 subjects enrolled in the study: 26 snuff users, 25 tobacco chewers, and 10 nonconsumers of nicotine. Using GC assessment of nicotine and cotinine (>or=200 ng/ml) as the standard, we found the sensitivity of the test strip to be 96% (25/26) for snuff users and 96% (24/25) for tobacco chewers. When compared with self-report, the sensitivity of the test strip was 92.3% (24/26) for snuff users and 84% (21/25) for tobacco chewers. The specificity for nonusers of nicotine was 100% (10/10) for both the self-report and GC conditions. These results suggest that a reagent-impregnated test strip is a rapid, valid, and user-friendly means of differentiating smokeless tobacco users from nonconsumers of tobacco. The intensity of the pink color on the test strip is proportional to the amount of nicotine or its metabolites present in urine and therefore offers a semiquantitative measure of nicotine consumption.
More Related Videos
09:25Methods to Evaluate Cytotoxicity and Immunosuppression of Combustible Tobacco Product Preparations
Published on: January 10, 2015
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Receiver Operating Characteristic Plot
Gas Chromatography: Types of Detectors-II
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...