X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Radiography of scoliosis: comparative dosimetry between conventional technique and digital fluorography]
G Gorincour1, K Barrau, S Waultier
1Service de Radiologie Pédiatrique, Hôpital Timone-Enfants, 264 Rue Saint Pierre, 13385 Marseille, France.
Objective:
Compare the irradiation delivered in conventional radiography and digital radiography by image intensifier during a scoliosis workup.
Patients And Methods:
Our prospective randomized study included 105 patients, all of whom were identified according to sociodemographic parameters as well as criteria evaluating the quality of the full front spinal x-ray at PA incidence. The entry dose at the scapula and the exit dose in interorbital, thyroid, mammary, and hypogastric projection was measured by thermoluminescent dosimeters.
Results:
The results of 71 girls and 28 boys, aged a mean 13.8 years with a mean weight of 47 kg were analyzed. At equal image quality, the entry dose was not significantly different between the two techniques; the mean exit dose reduction was 64% during digital acquisition. This reduction involved the interorbital (162%), mammary (43%), and thyroid (309%) regions. However, this system is more irradiating in the hypogastric region (34%).
Conclusion:
The dosimetric evaluation of the different imaging techniques used to explore the entirety of the spine should be part of radiologists' quality standard used to document their work and their choices.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...