Communication outcomes of critical imaging results in a computerized notification system
Hardeep Singh1, Harvinder S Arora, Meena S Vij
1Houston Center for Quality of Care and Utilization Studies, Michael E. DeBakey Veterans Affairs Medical Center and Department of Medicine, Section of Health Services Research, Baylor College of Medicine, Houston, TX, USA. hardeeps@bcm.tmc.edu
Objective:
Communication of abnormal test results in the outpatient setting is prone to error. Using information technology can improve communication and improve patient safety. We standardized processes and procedures in a computerized test result notification system and examined their effectiveness to reduce errors in communication of abnormal imaging results.
Design:
We prospectively analyzed outcomes of computerized notification of abnormal test results (alerts) that providers did not explicitly acknowledge receiving in the electronic medical record of an ambulatory multispecialty clinic.
Measurements:
In the study period, 190,799 outpatient visits occurred and 20,680 outpatient imaging tests were performed. We tracked 1,017 transmitted alerts electronically. Using a taxonomy of communication errors, we focused on alerts in which errors in acknowledgment and reception occurred. Unacknowledged alerts were identified through electronic tracking. Among these, we performed chart reviews to determine any evidence of documented response, such as ordering a follow-up test or consultation. If no response was documented, we contacted providers by telephone to determine their awareness of the test results and any follow-up action they had taken. These processes confirmed the presence or absence of alert reception.
Results:
Providers failed to acknowledge receipt of over one-third (368 of 1,017) of transmitted alerts. In 45 of these cases (4% of abnormal results), the imaging study was completely lost to follow-up 4 weeks after the date of study. Overall, 0.2% of outpatient imaging was lost to follow-up. The rate of lost to follow-up imaging was 0.02% per outpatient visit.
Conclusion:
Imaging results continue to be lost to follow-up in a computerized test result notification system that alerted physicians through the electronic medical record. Although comparison data from previous studies are limited, the rate of results lost to follow-up appears to be lower than that reported in systems that do not use information technology comparable to what we evaluated.
Related Concept Videos
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters assessment...