Related Experiment Video
Updated: Jul 15, 2026

Monitoring of Systemic and Hepatic Hemodynamic Parameters in Mice
Published on: October 4, 2014
Principals of hemodynamic monitoring
Patricio M Polanco1, Michael R Pinsky
1Division of Trauma, Department of Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA 15261, USA.
Background/Aims:
Hemodynamic monitoring is the cornerstone of patient management in the intensive care unit. However, to be used effectively its applications and limitations need to be defined and its values applied within the context of proven therapeutic approaches.
Methods:
Review of the physiological basis for monitoring and a review of the literature on its utility in altering patient outcomes.
Results:
Most forms of monitoring are used to prevent cardiovascular deterioration or restore cardiovascular wellness. However, little data support the generalized use of aggressive resuscitation protocols in all but the most acutely ill prior to the onset of organ injury. Outcomes improve with aggressive resuscitation in some patients presenting with early severe sepsis and in postoperative high-risk surgical patients.
Conclusions:
Monitoring should be targeted to meet the specific needs of the patient and should not be applied in a broad fashion and whenever possible it should be used as part of a treatment protocol of proven efficacy.
More Related Videos
05:01A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
09:05Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
Published on: January 30, 2015
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Holter Monitor: 24-Hour Monitoring
Measurement of Blood Pressure