Validation of numerical simulation with PIV measurements for two anastomosis models

Jun-Mei Zhang1, Leok Poh Chua, Dhanjoo N Ghista

  • 1School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore.

Insights

A 135-degree proximal anastomosis model for coronary artery bypass grafts (CABG) may reduce stenosis risk compared to a 90-degree model. This is due to more favorable hemodynamic parameters, potentially lowering intimal thickening and atherosclerosis.

Area of Science:

  • Cardiovascular Surgery
  • Biomedical Engineering
  • Fluid Dynamics

Background:

  • Coronary artery bypass graft (CABG) stenosis is influenced by hemodynamics.
  • Proximal anastomosis in CABG requires further investigation regarding stenosis.
  • Flow dynamics at the proximal anastomosis may impact stenosis initiation and progression.

Purpose of the Study:

  • To investigate hemodynamic differences between 90-degree and 135-degree proximal anastomosis models for CABG.
  • To validate numerical simulations of proximal anastomosis flow characteristics with experimental data.
  • To assess the potential of different anastomosis angles in mitigating stenosis and atherosclerosis.

Main Methods:

  • Designed and constructed 90-degree and 135-degree anastomotic models for CABG simulation.
  • Employed Particle Image Velocimetry (PIV) measurements on Pyrex glass models.
  • Validated numerical simulation results against experimental flow characteristics, velocity profiles, and wall shear stress (WSS).

Main Results:

  • Observed good agreement between numerical and experimental data for flow characteristics, velocity profiles, and WSS.
  • Identified disturbed flow patterns including stagnation points, flow separation, and vortices in both models.
  • Numerical analysis indicated the 135-degree model potentially reduces intimal thickening and atherosclerosis risk compared to the 90-degree model.

Conclusions:

  • The 135-degree proximal anastomosis model shows promise for reducing CABG stenosis.
  • Lower variation in time-averaged WSS and segmental average of WSSG in the 135-degree model suggest reduced atherosclerotic potential.
  • Hemodynamic factors at the proximal anastomosis are critical for graft patency and long-term outcomes.