Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
What technique should I use to measure cardiac output?
Christoph K Hofer1, Michael T Ganter, Andreas Zollinger
1Institute of Anesthesiology and Intensive Care Medicine, Triemli City Hospital, Switzerland. christoph.hofer@triemli.stzh.ch
Purpose Of Review:
Several less invasive cardiac output monitoring techniques are now commercially available and have the potential to replace the pulmonary artery catheter under certain clinical circumstances. The aim of this review is to give a synopsis of the currently available cardiac output measurement methods. This information should help in selecting the appropriate technique in a particular clinical setting.
Recent Findings:
An overview is given of the currently available techniques for cardiac output monitoring. Recent validation studies demonstrate that pulse wave analysis may be used reliably as an alternative to the pulmonary artery catheter in different clinical settings. The use of transesophageal echocardiography and Doppler measurements is limited due to high operator dependency, the partial carbon dioxide rebreathing technique should be applied in a precisely defined clinical setting to mechanically ventilated patients only, and pulsed dye densitometry as well as the bioimpedance technique are currently primarily applied in an investigational setting.
Summary:
Less invasive cardiac output monitoring techniques may replace the pulmonary artery catheter in different clinical settings considering the specific properties of these techniques. The pulmonary artery catheter, however, may still be recommended for cardiac output measurement in specific clinical situations when monitoring of pulmonary artery pressures is desirable.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...