[Non-invasive extended hemodynamic monitoring. Reduction of circulatory risk situations]
Background:
Cardiac output and the cardiac index (CI) are not routinely monitored during major abdominal surgery for economic as well as medical reasons. This practice, however, might be changed by the application of newer non-invasive technologies like the partial CO(2) rebreathing method based on the inverse Fick's principle. In this prospective randomized study we investigated the impact of a non-invasive monitoring of CI on the incidence of hemodynamic instability and interventions by the attending anesthesiologist during major abdominal surgery.
Patients And Methods:
Additionally to routine hemodynamic monitoring we measured CI using the partial CO(2) rebreathing method in 28 patients (9 female, 19 male) undergoing major abdominal surgery. In group I the anesthesiologists were aware of the results of the extended hemodynamic monitoring and in group II the attending anesthesiologist was blinded to the information obtained by these measurements of CI.
Results:
Groups did not differ with regard to the baseline hemodynamic parameters. We obtained 923 measurements in both groups and 95 situations of hemodynamic instability (CI<2.5 l/minxm(2)) were detected in group I compared to 147 situations in group II (p<0.05). There were significantly more hemodynamic interventions in group I than in group II (p<0.0001). The cardiac index remained higher in group I in comparison to group II (p<0.0001). Measurement of CI was the only method to detect situations of hemodynamic instability in our setting.
Conclusion:
The incidence of hemodynamic instability was significantly reduced during major abdominal surgery when anesthesiologists were aware of the measurement results of extended hemodynamic monitoring.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Cardiac Catheterization IV: Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.