Improved performance and maintenance in gas chromatography/isotope ratio mass spectrometry by precolumn solvent
Ulrich Flenker1, Moritz Hebestreit, Thomas Piper
1Manfred Donike Institute, German Sport University Cologne (DSHS), Carl-Diem-Weg 6, 50933 Cologne, Germany. uli@biochem.dshs-koeln.de
Abstract:
The crucial step in current concepts to interface isotope ratio mass spectrometry (IRMS) to gas chromatography (GC) is efficient solvent removal. This is due to the essential postcolumn conversion of the analytes into simple gases, which is performed by either combustion or pyrolysis. The capacity of this step merely suffices to convert the analytes. Already small amounts of solvent present in the respective furnace can cause severe damage. In conventional GC/IRMS interfaces, the solvent is removed after passage of the GC column. Either back-flushing or flow diversion is employed for this purpose. Both techniques necessitate the use of numerous components such as unions, tee pieces, valves, and capillary connections. Often this results in significant deterioration of the chromatographic resolution. In contrast, accurate GC/IRMS measurements require baseline separation of adjacent peaks. Moreover, maintenance of conventional interfaces may be tedious and time consuming, mostly because the numerous connections are prone to leakage. In order to avoid these drawbacks, we propose a concept to efficiently remove the solvent before passage of the GC column. It is based on the use of a cooled injection system operated in solvent vent mode, where the solvent elimination is supported by an auxiliary pump. Most unions and tee pieces thus can be removed. The chromatographic resolution is considerably enhanced. In particular, analysis of high-boiling and polar compounds can be improved. At the same time, the maintenance of the system is significantly facilitated. Under the chosen conditions, partial losses of low-boiling analytes during solvent elimination were not associated with significant isotope fractionation.
More Related Videos
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: