Related Experiment Video
Updated: Feb 10, 2026

Knotless Independent Double-Row Repair and Biceps Augmentation for Anterosuperior Rotator Cuff Tears
Published on: January 23, 2026
Arthroscopic rotator cuff repair using the suture loop shuttle technique
Raymond Thal1, W Bryan Jennings, Wendy L Heusch
1Town Center Orthopaedic Associates, Reston, Virginia 20190, USA. RayThal@aol.com
Abstract:
With the arthroscope in the posterior portal, several suture loops are passed through the rotator cuff via the superior lateral portal before the first anchor is inserted. The suture loop is created by passing both free ends of a No. 2 monofilament (48-inch Prolene, Ethilon, or PDS; Ethicon, Somerville, NJ) suture into an arthroscopic suture passing device. The free ends and the loop of each suture loop are temporarily transferred into the anterior cannula. Anchor insertion and passage of the anchored sutures are performed from posterior to anterior. With standard suture anchors, the loop end of the suture loop must be located on the undersurface of the cuff. The suture anchors are inserted one at a time through the superior lateral portal and are placed into the prepared holes. Anchored sutures are temporarily pulled out through the inferior lateral portal. Next, the free ends of the most posterior suture loop are retrieved through the superior lateral portal. The looped end of this suture loop is retrieved through the inferior lateral portal. The suture loop is used to shuttle a single anchored suture through the rotator cuff and out through the superior lateral portal. Then, the other anchored suture is retrieved through the superior lateral portal with a suture grasper and tied.
More Related Videos
06:41A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
07:22Arthroscopic Management of Massive Irreparable Rotator Cuff Tears: Whole Rotator Cable Reconstruction Using Proximal Biceps Tendon Autograft
Published on: June 6, 2025
Related Concept Videos
Mismatch Repair
Overview of DNA Repair
Chemically...
Base Excision Repair
The first step of...
Nucleotide Excision Repair
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Long-patch Base Excision Repair