An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Influence of two changes in the composition of an acrylic bone cement on its handling, thermal, physical, and
1Department of Mechanical Engineering, The University of Memphis, Memphis, TN 38152-3180, USA. glewis@memphis.edu
Abstract:
This study is a contribution to the growing body of work on the influence of changes in the composition of an acrylic bone cement on various properties of the curing and cured material. The focus is on one commercially-available acrylic bone cement brand, Surgical Simplex P, and three variants of it and a series of properties, namely, setting time, maximum exotherm temperature, activation energy and frequency factor for the polymerization reaction, diffusion coefficient for the uptake of phosphate buffered saline, at 37 degrees C, ultimate compressive strength (UCS), plane-strain fracture toughness, fatigue life (under fully-reversed tension-compression stress), hardness (H) and elastic modulus (both determined using quasi-static nanoindentation), and the variation of the storage and loss moduli with frequency of the applied force in a dynamic nanoindentation test. It was found that (a) a 68% reduction in the volume of the activator, N,N dimethyl-4-toluidine, relative to the total volume of the liquid monomer (the amounts of all the constituents in the powder and of the hydroquinone in the liquid monomer remaining unchanged) led to, for example, a significant decrease in the rate of the polymerization reaction, at 37 degrees C (c') and a significant increase in H; and (b) the elimination of the pre-polymerized poly (methyl methacrylate) beads in the powder (the amounts of all the other powder constituents and those of the liquid monomer remaining unchanged) led to, for example, a significant drop in c' and a significant increase in UCS. Thus, these findings suggest a strategy for optimizing the composition of an acrylic bone cement.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Soundness of Cement
Mortar Properties
Setting Time of Cement
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...