Related Experiment Video
Updated: Jul 15, 2026

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
A comparison of the effectiveness of open and closed endotracheal suction
Beverley Copnell1, David G Tingay, Nicholas J Kiraly
1Royal Children's Hospital, Department of Neonatology, Flemington Rd, VIC 3052, Parkville, Australia. bev.copnell@rch.org.au
Objective:
To compare the effectiveness of open and closed endotracheal suction in recovering thin and thick secretions in normal and injured lungs during conventional and high frequency ventilation.
Design And Setting:
Randomised study in a paediatric intensive care model in the animal research laboratory of a tertiary paediatric hospital.
Subjects:
16 New Zealand White rabbits.
Interventions:
Anaesthetised animals were intubated with a 3.5-mm endotracheal tube. Simulated thin and thick secretions (iopamidol 2 ml, a watery radio-opaque fluid, and fluorescent mucin 1 ml) were instilled in turn 1 cm below the tube tip through a catheter placed via a tracheostomy. Open or closed suction, randomly assigned, was applied for 6s at -140 mmHg using a 6-F gauge catheter. Following lung injury with repeated saline lavage the procedure was repeated on conventional and high frequency ventilation.
Measurements And Results:
Iopamidol recovery was determined by digitally subtracting the post-contrast and post-suction radiographic images. Mucin recovery was determined by fluorescence assay of the aspirate. In the normal lung similar amounts were recovered by both suction methods. In the lavaged lung closed suction recovered less iopamidol during conventional (22 +/- 7.5%) and high frequency ventilation (11 +/- 2.4%) than open suction (36 +/- 2% and 22 +/- 8.1%, respectively). Mucin recovery was less with closed suction during conventional 32 +/- 28 microl) and high frequency ventilation (30 +/- 31 microl) than with open suction (382 +/- 235 microl and 24 +/- 153 microl).
Conclusions:
In the injured lung closed suction was less effective than open suction at recovering thin and thick simulated secretions, irrespective of ventilation mode.
Related Concept Videos
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.