Related Experiment Video
Updated: Jul 15, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Spectrofluorimetric estimation of norepinephrine using ethylenediamine condensation method
Mohammad Mainul Karim1, Seikh Mafiz Alam, Sang Hak Lee
1Department of Chemistry, Kyungpook National University, Taegu 702-701, South Korea.
This study presents a simple, sensitive method for measuring norepinephrine (NE) using mercury (II) nitrate and ethylenediamine (EDA). The assay achieves a low detection limit of 2.5 nM, suitable for biological samples.
Area of Science:
- Analytical Chemistry
- Biochemistry
- Pharmacology
Background:
- Norepinephrine (NE) is a crucial neurotransmitter and hormone.
- Accurate quantification of NE is vital for diagnosing and monitoring various physiological and pathological conditions.
- Existing methods for NE determination may lack sensitivity, simplicity, or be prone to interference.
Purpose of the Study:
- To develop a simple and highly sensitive method for norepinephrine determination.
- To validate the method's performance using biological samples and pharmaceutical preparations.
- To investigate and mitigate potential interferences, particularly from dopamine (DA).
Main Methods:
- Oxidation of norepinephrine (NE) using mercury (II) nitrate.
- Condensation of the oxidation product with ethylenediamine (EDA) to form a fluorescent compound.
- Enhancement of fluorescence intensity using acetone and measurement at specific wavelengths (excitation: 420 nm, emission: 507 nm).
- Application of first derivative synchronous fluorimetry with peak-to-zero technique to eliminate dopamine interference.
Main Results:
- A linear relationship between fluorescence intensity and NE concentration was observed in the range of 0.01 µM–0.014 mM.
- The method demonstrated a high correlation coefficient (0.99813) and a low detection limit (2.5 nM).
- Recovery efficiency in urine samples ranged from 95% to 98.62%, indicating good accuracy.
- Successful application of the method for determining NE in injection solutions.
Conclusions:
- The proposed method offers a simple, sensitive, and reliable approach for norepinephrine quantification.
- The method is effective in biological matrices like urine and in pharmaceutical formulations.
- The developed fluorimetric technique effectively overcomes interference from dopamine.
More Related Videos
12:07Microwave-assisted Intramolecular Dehydrogenative Diels-Alder Reactions for the Synthesis of Functionalized Naphthalenes/Solvatochromic Dyes
Published on: April 1, 2013
12:48Construction of Cell-based Neurotransmitter Fluorescent Engineered Reporters (CNiFERs) for Optical Detection of Neurotransmitters In Vivo
Published on: May 12, 2016