Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Circuit Terminology01:14

Circuit Terminology

An electrical network is a system composed of interconnected elements, such as resistors, capacitors, inductors, and voltage or current sources. Unlike a circuit, an electrical network does not necessarily form a closed path. In other words, while all circuits can be considered networks due to their interconnected nature, not every network qualifies as a circuit.
A circuit, on the other hand, is also an interconnected system of electrical elements but must contain one or more closed paths.
Electro-mechanical Systems01:19

Electro-mechanical Systems

Electromechanical systems are intricate configurations that effectively combine electrical and mechanical elements to achieve a desired outcome. Central to many of these systems is the DC motor, a device that converts electrical energy into mechanical motion, enabling various applications ranging from simple fans to complex robotic mechanisms.
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
Anchoring Junctions01:03

Anchoring Junctions

Anchoring junctions are multiprotein complexes that help cells connect to other cells and the extracellular matrix. Anchoring junctions are present on the lateral and basal surfaces of cells, providing strong and flexible connections. Focal adhesions are often formed due to cell interactions with the ECM substrata, which initiate signal transduction via kinase cascades and other mechanisms. Together, they provide stability and tissue integrity. There are three types of anchoring junctions:...
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
Impedance Combination01:21

Impedance Combination

Consider a string of christmas lights, each bulb symbolizing an impedance element. In this series configuration, the flow of electric current remains uniform across every component. This behavior aligns with Kirchhoff's Voltage Law (KVL), which asserts that the total impedance in such a setup equals the sum of individual impedances—akin to resistors in series. It follows that the voltage from the power source is distributed proportionally among these components, adhering to the voltage division...
Spindle Assembly02:50

Spindle Assembly

Spindle assembly occurs through three, often coexisting, pathways – the centrosome-mediated pathway, the chromatin-mediated pathway, and the microtubule-mediated pathway – collectively contributing to form a robust spindle apparatus.
In most cells, centrosomes are the primary microtubule nucleation centers. In the centrosome-mediated pathway, the G2-prophase transition triggers centrosome maturation and increased microtubule nucleation. Progressive nucleation results in a microtubule array...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Operative Orthopadie und Traumatologie·2026
Same author

[General principles of biopsy technique and approaches in soft tissue and bone sarcomas].

Operative Orthopadie und Traumatologie·2026
Same author

[Tumour-related extra-articular knee joint resection].

Operative Orthopadie und Traumatologie·2026
Same author

[Infectious bacterial symphysitis (purulent infection of the pubic symphysis) in a urological setting-a descriptive study and treatment algorithm].

Urologie (Heidelberg, Germany)·2025
Same author

The role of body composition and visceral fat in osteoporosis subtype differentiation: Insights from bioelectrical impedance analysis.

Journal of orthopaedics·2025
Same author

Diagnosis of periprosthetic loosening of total hip and knee arthroplasty using <sup>68</sup>Gallium-Zoledronate PET/CT.

Archives of orthopaedic and trauma surgery·2024

Related Experiment Video

Updated: Jul 15, 2026

A Lightweight Drive Implant for Chronic Tetrode Recordings in Juvenile Mice
06:34

A Lightweight Drive Implant for Chronic Tetrode Recordings in Juvenile Mice

Published on: June 2, 2023

[The morse taper junction in modular revision hip replacement].

S Gravius1, T Mumme, S Andereya

  • 1Orthopädische Universitätsklinik der Rheinisch-Westfälischen Technischen Hochschule Aachen, Aachen. sascha.gravius@web.de

Zeitschrift Fur Orthopadie Und Unfallchirurgie
|May 12, 2007
PubMed
Summary

Morse taper junctions in hip revision implants are prone to failure. This retrieval analysis examined a titanium implant after 11.5 years, highlighting potential issues with these critical components.

More Related Videos

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
07:45

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report

Published on: August 4, 2022

Hybrid Microdrive System with Recoverable Opto-Silicon Probe and Tetrode for Dual-Site High Density Recording in Freely Moving Mice
08:57

Hybrid Microdrive System with Recoverable Opto-Silicon Probe and Tetrode for Dual-Site High Density Recording in Freely Moving Mice

Published on: August 10, 2019

Related Experiment Videos

Last Updated: Jul 15, 2026

A Lightweight Drive Implant for Chronic Tetrode Recordings in Juvenile Mice
06:34

A Lightweight Drive Implant for Chronic Tetrode Recordings in Juvenile Mice

Published on: June 2, 2023

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
07:45

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report

Published on: August 4, 2022

Hybrid Microdrive System with Recoverable Opto-Silicon Probe and Tetrode for Dual-Site High Density Recording in Freely Moving Mice
08:57

Hybrid Microdrive System with Recoverable Opto-Silicon Probe and Tetrode for Dual-Site High Density Recording in Freely Moving Mice

Published on: August 10, 2019

Area of Science:

  • Biomaterials Science
  • Orthopedic Surgery
  • Implant Retrieval Analysis

Background:

  • Morse taper junctions in modular hip revision replacements are susceptible to fretting, corrosion, and component dissociation.
  • These issues can lead to implant failure and adverse patient outcomes.
  • Understanding the long-term behavior of these junctions is crucial for improving implant design.

Purpose of the Study:

  • To present a retrieval analysis of a specific titanium modular hip revision replacement's Morse taper junction.
  • To discuss the significance of Morse taper junctions in modular hip revision arthroplasty based on current literature and case findings.

Main Methods:

  • Retrieval analysis of a MRP-titanium modular revision replacement (Peter Brehm GmbH).
  • Examination of the Morse taper junction after 11.5 years of in vivo use.
  • Literature review on the role and failure modes of Morse taper junctions in hip revision surgery.

Main Results:

  • The study analyzed a retrieved MRP-titanium modular hip revision implant.
  • The Morse taper junction was examined after 11.5 years of clinical service.
  • The findings are discussed in the context of known failure mechanisms for such junctions.

Conclusions:

  • Morse taper junctions in modular hip revision implants require careful consideration due to potential failure modes.
  • This case report contributes to the understanding of in vivo performance of titanium modular hip revision components.
  • Further research into optimizing Morse taper junction design and material is warranted to enhance long-term implant survival.