Prevalence, challenges, and solutions for (18)F-FDG PET studies of obese patients: a technologist's perspective
Crystal D Botkin1, Medhat M Osman
1Nuclear Medicine Technology Program, Department of Medical Imaging and Radiation Therapeutics, Doisy College of Health Sciences, Saint Louis University, St. Louis, Missouri 63110, USA.
Unlabelled:
Obesity has reached epidemic proportions in the United States; hence, it is frequently encountered in patients undergoing (18)F-FDG PET studies. The purpose of the current study was to present a technologist's perspective on the prevalence of obesity and the challenges and solutions in imaging obese patients in our PET facility.
Methods:
From October 2002 to October 2003, whole-body (18)F-FDG PET was performed on 1,164 patients with a known or suspected malignancy. Images were acquired 45-60 min after (18)F-FDG injection (7.4 MBq [0.2 mCi]/kg, with a maximum of 925 MBq [25 mCi]) on a PET scanner using a 4-min emission and 3-min transmission time per bed position. A database was maintained of patient height and weight, and body mass index (BMI) was calculated. Patient obesity was classified as overweight (BMI > or = 25 kg/m(2)), obese (BMI > or = 30 kg/m(2)), or malignantly obese (BMI > or = 40 kg/m(2)). In addition, PET technologists recorded any problems and attempted solutions related to the patient weight.
Results:
BMI calculations showed that 528 patients (45.4%) were overweight or obese (322 men and 206 women; mean age, 55 y). Of those, 201 (38%) were overweight, 270 (51%) were obese, and 57 (11%) were malignantly obese. Problems encountered in these patients included difficult intravenous access (15%), difficult patient positioning (10%), patient motion (7%), an incomplete study (emission only) (1%), and potentially higher radiation exposure to the technologist because of extra time spent near the patient. Attempted solutions included adjusting the schedule to allow more time per patient, adjusting the dose based on body weight, using varied positioning techniques, dividing the study to allow a respite between different image combinations, and dividing time spent with obese patients among the technologists involved.
Conclusion:
Excessive body weight and related problems have commonly been encountered in our PET facility. (18)F-FDG PET studies of obese patients represent an ongoing challenge, which requires patient-tailored solutions to avoid compromising image quality and risking higher radiation exposure to the technologists.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
Published on: May 2, 2012
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...