Quantitative structure-(chromatographic) retention relationships
Related Experiment Video
Updated: Jul 15, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
1Chemical Research Center, Hungarian Academy of Sciences, P.O. Box 17, H-1525 Budapest, Hungary. heberger@chemres.hu
Abstract:
Since the pioneering works of Kaliszan (R. Kaliszan, Quantitative Structure-Chromatographic Retention Relationships, Wiley, New York, 1987; and R. Kaliszan, Structure and Retention in Chromatography. A Chemometric Approach, Harwood Academic, Amsterdam, 1997) no comprehensive summary is available in the field. Present review covers the period of 1996-August 2006. The sources are grouped according to the special properties of kinds of chromatography: Quantitative structure-retention relationship in gas chromatography, in planar chromatography, in column liquid chromatography, in micellar liquid chromatography, affinity chromatography and quantitative structure enantioselective retention relationships. General tendencies, misleading practice and conclusions, validation of the models, suggestions for future works are summarized for each sub-field. Some straightforward applications are emphasized but standard ones. The sources and the model compounds, descriptors, predicted retention data, modeling methods and indicators of their performance, validation of models, and stationary phases are collected in the tables. Some important conclusions are: Not all physicochemical descriptors correlate with the retention data strongly; the heat of formation is not related to the chromatographic retention. It is not appropriate to give the errors of Kovats indices in percentages. The apparently low values (1-3%) can disorient the reviewers and readers. Contemporary mean interlaboratory reproducibility of Kovats indices are about 5-10 i.u. for standard non polar phases and 10-25 i.u. for standard polar phases. The predictive performance of QSRR models deteriorates as the polarity of GC stationary phase increases. The correlation coefficient alone is not a particularly good indicator for the model performance. Residuals are more useful than plots of measured and calculated values. There is no need to give the retention data in a form of an equation if the numbers of compounds are small. The domain of model applicability of models should be given in all cases.
More Related Videos
07:45Technical Approach for Structural Analysis of an Unknown Compound in Huoxiang Zhengqi Oral Liquid based on Linear Ion Trap Mass Spectrometry
Published on: April 3, 2026
05:03Quantitative Analysis of Dietary Vitamin A Metabolites in Murine Ocular and Non-Ocular Tissues Using High-Performance Liquid Chromatography
Published on: December 27, 2024
Related Concept Videos
Chromatographic Methods: Terminology
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Affinity Chromatography