Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Influence of monitor chamber calibration on virtual Wedge dosimetry
1Department of Medical Physics, CancerCare Manitoba, 675 McDermot Ave., Winnipeg, Manitoba, Canada R3E 0V9. kyle.malkoske@cancercare.md.ca
Abstract:
We have investigated the influence of the linear accelerator (LINAC) monitor chamber calibration on the dosimetry of Siemens Virtual Wedge (VW.) The doses delivered in the three phases of wedge delivery (initial gap, sweep portion, and open field) utilize the ionization current generated in two dose monitoring ion chambers (MONITOR 1 and MONITOR 2) in the LINAC to control the wedge delivery. We intentionally offset the calibration of each of these chambers by +/- 3% and observed up to a 13% change in the dose along the wedge profile for a 6 MV beam at a field size of 20 x 20 cm2. If the calibration of one of the two dose monitoring chambers changed independently then the relative dose at points along the wedge profile were affected. Furthermore, the percentage change in dose varied across the wedge profile thereby affecting the wedge angle as well as the central axis wedge factor. We also present equations for calculating the change in dose at a position along the wedge profile as a function of monitor chamber calibration. A comparison with measurement showed that our theoretical predictions were accurate to within +/- 1.7%. The equations have proven useful tools in evaluating periodic drifts in VW dosimetry.
More Related Videos
10:23A Machine-Vision Approach to Transmission Electron Microscopy Workflows, Results Analysis and Data Management
Published on: June 23, 2023
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Uncertainty in Measurement: Reading Instruments