Related Experiment Video
Updated: Jul 15, 2026

A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Manual planimetric measurement of carotid plaque volume using three-dimensional ultrasound imaging
Anthony Landry1, Craig Ainsworth, Chris Blake
1Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8, Canada.
Abstract:
We investigated the utility of three manual planimetric methods to quantify carotid plaque volume. A single observer measured 15 individual plaques from 15 three-dimensional (3D) ultrasound (3D US) images of patients ten times each using three different planimetric approaches. Individual plaque volumes were measured (range: 32.6-597.1 mm3) using a standard planimetric approach (M1) whereby a plaque end was identified and sequential contours were measured. The same plaques were measured using a second approach (M2), whereby plaque ends were first identified and the 3D US image of the plaque was then subdivided into equal intervals. A third method (M3) was used to measure total plaque burden (range: 165.1-1080.0 mm3) in a region (+/- 1.5 cm) relative to the carotid bifurcation. M1 systematically underestimated individual plaque volume compared to M2 (V2 = V1 + 14.0 mm3, r = 0.99, p = 0.006) due to a difference in the mean plaque length measured. Coefficients of variance (CV) for M1 and M2 decrease with increasing plaque volume, with M2 results less than M1. Root mean square difference between experimental and theoretical CV for M2 was 3.2%. The standard deviation in the identification of the transverse location of the carotid bifurcation was 0.56 mm. CVs for plaque burden measured using M3 ranged from 1.2% to 7.6% and were less than CVs determined for individual plaque volumes of the same volume. The utility of M3 was demonstrated by measuring carotid plaque burden and volume change over a period of 3 months in three patients. In conclusion, M2 was determined to be a more superior measurement technique than M1 to measure individual plaque volume. Furthermore, we demonstrated the utility of M3 to quantify regional plaque burden and to quantify change in plaque volume.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
10:41Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021