Enhanced parameter estimation methods for noisy SPECT data
Related Experiment Video
Updated: Jul 14, 2026

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
Published on: August 19, 2021
Lingfeng Wen1, Stefan Eberl, Hon-Chit Choi
1Biomedical and Multimedia Information Technology Group, School of Information Technologies, The University of Sydney, Sydney, Australia. wenlf@it.usyd.edu.au
Abstract:
Functional imaging with PET and SPECT is capable of visualizing subtle changes in physiological function in vivo, which aids in the early diagnosis of disease. Quantitative functional parameters are usually derived by curve fitting the dynamic data of a functional imaging study. However, the intrinsic high level of noise and low signal to noise ratio can lead to instability in the parameter estimation and give rise to non-physiological parameter estimates. Clustering techniques have been applied to improve signal to noise ratio and the reliability of parametric image generation, but these may enhance partial volume effects (PVE) and result in biased estimates for small structures. Therefore, a systematic study was performed using computer simulations of SPECT data and the generalized linear least square algorithm (GLLS) to evaluate the ability of three proposed enhanced methods and a clustering-aided method to improve the reliability of parametric image generation. The results demonstrate that clustering with sufficient cluster numbers ameliorated PVE and provided noise-insensitive parameter estimates. The enhanced GLLS method with a prior volume of distribution and bootstrap Monte Carlo resampling improved the reliability of the curve fitting, and is thus suitable for application to noisy SPECT data.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...