Related Experiment Video
Updated: Jul 14, 2026

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Validation of renal oxidative metabolism measurement by positron-emission tomography
Laurent Juillard1, Sandrine Lemoine, Marc F Janier
1Département De Néphrologie, Hôpital Edouard Herriot, Hospices Civils de Lyon, Lyon, France. laurent.juillard@chu-lyon.fr
Abstract:
Either in research or in clinical practice, the exploration of renal oxidative metabolism is limited by the lack of noninvasive measurement. Positron-emission tomography using carbon-11 acetate may estimate tissue oxidative metabolism by measuring acetate turnover in the Krebs cycle. Although extensively studied in cardiology, this method has never been validated for renal oxidative metabolism measurement. The aim of this study is the validation of acetate turnover compared with the invasive renal oxygen consumption measurement. Renal oxygen consumption and tubular sodium reabsorption were measured invasively in 10 anesthetized pigs. Simultaneously, acetate turnover was estimated by the clearance of carbon-11 acetate in the renal cortex, after a 166-MBq injection of carbon-11 acetate. Renal oxidative metabolism was measured under various conditions induced by mechanical and pharmacological interventions. Renal oxygen consumption and acetate turnover varied on a wide range from 0.05 to 0.29 mmol min(-1) (>5-fold) and from 0.025 to 0.188 minutes(-1) (>7-fold), respectively. Acetate turnover was very significantly correlated with renal oxygen consumption (P<0.0001; R=0.82) and tubular sodium reabsorption (P=0.001; R=0.67). This study demonstrates that acetate turnover measures renal oxidative metabolism noninvasively and quantitatively, consistent with changes in tubular sodium reabsorption. This method may be applied to assess oxidative metabolism in animal models and in humans.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

