Dosimetry accuracy as a function of seed localization uncertainty in permanent prostate brachytherapy: increased seed
Yi Su1, Brian J Davis, Keith M Furutani
1Biomedical Imaging Resource, Mayo Clinic College of Medicine, Rochester, MN 55905, USA.
Abstract:
The variation of permanent prostate brachytherapy dosimetry as a function of seed localization uncertainty was investigated for I-125 implants with seed activities commonly employed in contemporary practice. Post-implant imaging and radiation dosimetry data from nine patients who underwent permanent prostate brachytherapy served as the source of clinical data for this simulation study. Gaussian noise with standard deviations ranging from 0.5 to 10 mm was applied to the seed coordinates for each patient dataset and 1000 simulations were performed at each noise level. Dose parameters, including D90, were computed for each case and compared with the actual dosimetry data. A total of 81 000 complete sets of post-brachytherapy dose volume statistics were computed. The results demonstrated that less than 5% deviation of prostate D90 can be expected when the seed localization uncertainty is 2 mm, whereas a seed localization uncertainty of 10 mm yielded an average decrease in D90 of 33 Gy. The mean normalized decrement in the prostate V100 was 10% at 5 mm uncertainty. Implants with greater seed number and larger prostate volume correlated with less sensitivity of D90 and V100 to seed localization uncertainty. Estimated target volume dose parameters tended to decrease with increasing seed localization uncertainty. The bladder V100 varied more significantly both in mean and standard deviation as compared to the urethra V100. A larger number of implanted seeds also correlated to less sensitivity of the bladder V100 to seed localization uncertainty. In contrast, the deviation of urethra V100 did not correlate with the number of implanted seeds or prostate volume.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Biological Effects of Radiation
Uncertainty in Measurement: Accuracy and Precision
Propagation of Uncertainty from Systematic Error
Accuracy and Precision
Propagation of Uncertainty from Random Error