Related Experiment Video
Updated: Jul 14, 2026

AC Electrokinetic Phenomena Generated by Microelectrode Structures
Published on: July 28, 2008
AC electrothermal manipulation of conductive fluids and particles for lab-chip applications
1The University of Tennessee, Department of Electrical and Computer Engineering, Knoxville, TN 37996, USA.
Abstract:
AC electrokinetics has shown great potential for microfluidic functions such as pumping, mixing and concentrating particles. So far, electrokinetics are typically applied on fluids that are not too conductive (<0.02 S/m), which excludes most biofluidic applications. To solve this problem, this paper seeks to apply AC electrothermal (ACET) effect to manipulate conductive fluids and particles within. ACET generates temperature gradients in the fluids, and consequently induces space charges that move in electric fields and produce microflows. This paper reports two new ACET devices, a parallel plate particle trap and an asymmetric electrode micropump. Preliminary experiments were performed on fluids with conductivity at 0.224 S/m. Particle trapping and micropumping were demonstrated at low voltages, reaching approximately 100 microm/s for no more than 8 Vrms at 200 kHz. The fluid velocity was found to depend on the applied voltage as V(4), and the maxima were observed to be approximately 20 microm above the electrodes.