Fibreoptic intubation using three airway conduits in a manikin: the effect of operator experience
I Hodzovic1, J Petterson, A R Wilkes
1Department of Anaesthetics and Intensive Care Medicine, Cardiff University, Heath Park, Cardiff, UK. Hodzovic@cf.ac.uk
Abstract:
In a randomised cross-over study, 72 anaesthetists (24 Senior House Officers, 24 Specialist Registrars and 24 Consultants) attempted to place a fibreoptic scope in the trachea of a manikin using three airway conduits: the Berman airway, the LMA Classic(trade mark) and the intubating laryngeal mask airway. The time for insertion of the airway conduit, delivery of two breaths and fibreoptic scope placement in the trachea was the primary endpoint. These overall times were significantly shorter (median [interquartile range]) using the LMA Classic (36 [28-45]) than via the intubating laryngeal mask (54 [42-79]) and the Berman airway (45 [33-80]), p < 0.0001. Senior House Officers were significantly slower than both Specialist Registrars and Consultants (p < 0.0001). The LMA Classic was considered to be the easiest conduit to use for fibreoptic scope placement by all grades of anaesthetists. We conclude that the LMA Classic is the most effective conduit for fibreoptic scope placement especially for anaesthetists with limited experience in its use.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required