Equilibrium and kinetic analysis of CO2-N2 adsorption separation by concentration pulse chromatography
1Department of Chemical Engineering, Faculty of Engineering, University of Ottawa, Ottawa, Ontario, Canada.
Abstract:
CO2 and N(2) adsorption kinetics and equilibrium behaviours have been studied with silicalite, NaY and 13X by using concentration pulse chromatography for the separation of these gases in the present study. Adsorption Henry's Law constants, the heat of adsorption values, micropore diffusion coefficients and corresponding activation energies are determined experimentally and the three different mass transfer mechanisms are discussed. From the equilibrium data, the corresponding separation factors are obtained for the adsorption separation processes. The heat of adsorption values as well as the Henry's Law adsorption equilibrium constants of CO(2) are much higher than those of N(2) for all the adsorbents studied. 13X, NaY and silicalite all have good separation factors for CO(2)/N(2) system based on equilibrium processes. The order of the equilibrium separation factors is 13X (Ceca)>13X (Zeochem)>NaY (UOP)>>silicalite (UOP). Equilibrium selectivity favours CO(2) over N(2). Micropore diffusion resistance is the definite dominant mass transfer mechanism for CO(2) with silicalite and NaY.
More Related Videos
Related Concept Videos
Analyte Adsorption and Distribution
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...


