Cholesterol Efflux Assay
Published on: March 6, 2012
Advantages and disadvantages of serum cholesterol determination by the kinetic vs the end point method
Pornpen Srisawasdi1, Martin H Kroll, Porntip H Lolekha
1Division of Clinical Chemistry, Department of Pathology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Abstract:
Enzymatic assays for cholesterol determination can use an end point or a kinetic method. We evaluated and compared the performance of these methods. We constructed user-defined methods on 3 automated analyzers using Streptomyces cholesterol reagents to evaluate the analytic performance of both methods. Linearity (700-900 mg/dL) and stability of reagents (5-11 weeks) depended on the analyzers. The coefficients of variation for imprecision were 2.41% to 2.99% and 3.78% to 5.52% for the end point and kinetic methods, respectively. The end point method showed less bias at decision cut points (-0.8% to 1.3%) than did the kinetic method (-1.1% to 3.6%) but was more affected by interfering substances.The advantages of the end point over the kinetic method are better precision and lower reagent cost. The end point imprecision fell within National Cholesterol Education Program guidelines (
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Introduction to Enzyme Kinetics
The experimenter can then plot the initial reaction rate or velocity (Vo) of a given trial against the substrate concentration ([S]) to obtain a graph of the reaction properties. For many enzymatic reactions involving a...
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...
Determination of Michaelis Constant and Maximum Elimination Rate
These parameters can be estimated by analyzing plasma concentration data post-drug administration. A notable example of this application is phenytoin, a drug with capacity-limited kinetics. It's recommended that phenytoin should be administered at two...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...