[Examination of types of exposure and management methods for nurses in interventional radiology]
Hiroshige Mori1, Kichiro Koshida, Tomonori Fujii
1Department of Radiology, Hokkaido Social Insurance Hospital.
Abstract:
Although a large number of studies have been done on exposure to operators and doctors during interventional radiology(IVR), there have been very few reports on nurses. This study was carried out to clarify the situation regarding exposure for nurses, and provides examples of how to estimate and manage. We measured space dose-rate distributions with an ionization survey meter, and personal exposure dose by a small fluorescent grass dosimeter(Dose Ace). The experimental results disclosed that there tended to be two types of exposure depending on the task performed. Head and neck(collar level)were associated with the highest exposure dose, which was observed in nurses assisting operators. Alternatively, knees showed the highest exposure dose, which was observed in nurses observing and assisting the patient. When estimation of skin equivalent exposure at the knees is needed, it can be calculated by using the value measured at the collar level. Furthermore, in estimating exposure dose, the directional and energy characteristics of personal dosimeters should be considered adequate. For radiation management, a circular protective sheet can be placed around the patient's lower area and a protective screen near the patient's head, and basic and practical education can be given. We concluded that these are highly useful for the personal monitoring of nurses engaged in IVR.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Cardiac Catheterization IV: Nursing Management
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT