Abstract:
Altered autonomic control of heart rate (HR) rhythm during exposure to particulate matter (PM) has been suggested in human and animal studies. Our lab has shown strain variation in HR regulation between quiescent C3H/HeJ (C3) and C57BL/6J (B6) mice: that is, C3 mice show a consistently higher HR by approximately 80 bpm compared with B6 mice during a normal 24-h circadian cycle. In the current study, we hypothesize that the balance between sympathetic and parasympathetic control of HR during PM exposure varies between C3 and B6 mice. Radiotelemeters were implanted in C3 and B6 mice to measure HR responses and HR variability (HRV) parameters during successive 3-h exposures to filtered air (FA) or carbon black (CB, < 300 mug/m3). Exposures were repeated following administration of saline or parasympathetic (PS; atropine, 0.5 mg/kg i.p.) and sympathetic (S; propranolol, 1 mg/kg i.p.) blockade to study the autonomic regulation of HR during CB exposure. During FA exposure with saline, a significantly (p < .05) greater 3-h average HR response (bpm +/- SEM) occurred in C3 compared with B6 mice (496 +/- 22 vs. 427 +/- 3). With PS blockade, the strain difference between C3 and B6 mice was not evident (485 +/- 23 vs. 503 +/- 61). With S blockade, the 3-h average HR responses for C3 mice were significantly (p < .05) reduced compared with saline (413 +/- 18 vs. 392 +/- 15 for B6). During CB exposure with saline, HR responses were again significantly (p < 0.05) elevated in C3 compared with B6 mice, but these HR responses were not different relative to FA exposure. With S blockade, HR was significantly (p < .05) elevated in B6 mice during CB relative to FA, but was unchanged in C3 mice. Collectively, these results suggest that strain variation in HR regulation is due to a robust PS tone evident in B6 mice and a predominant S tone in C3 mice. Furthermore, CB exposure alters HR regulation in B6 mice by modulating a withdrawal of PS tone. Finally, strain variation in HR between B6 and C3 mice in responding to acute PM exposure implies that robust genetic determinants modulate altered autonomic regulation in susceptible individuals.
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...