Related Experiment Video
Updated: Jul 14, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Rapid, simple and effective technical procedure for the regeneration of IgG and HSA affinity columns for proteomic
R Millioni1, L Puricelli, E Iori
1Department of Clinical and Experimental Medicine, Chair of Metabolism, University of Padova, Padova, Italy.
Abstract:
In plasma and serum, the presence of high-abundance proteins can overwhelm the signals of low-abundance proteins, which then become undetectable either by two-dimensional gels or chromatographic techniques. Therefore, depletion of abundant proteins is a prerequisite to detect low-abundance components. Furthermore, the regeneration of pre-purification tools could be money-saving. We applied an affinity chromatography kit to remove albumin and the immunoglobulin chains from plasma and propose a simple and effective technical procedure for the regeneration of these affinity columns.