Related Experiment Video
Updated: Jul 14, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Trended cosinor change model for analyzing hemodynamic rhythm patterns in hemodialysis patients
Ken Kelley1, Robert P Light, Rajiv Agarwal
1Inquiry Methodology Program, Indiana University, Bloomington, IN, USA.
Abstract:
To describe circadian blood pressure (BP) patterns and linear interdialytic changes, a model was developed to describe simultaneously both the straight line change and oscillatory variation in BP and heart rate over an interdialytic interval in hemodialysis patients. Using this trended cosinor model, we simultaneously compared the impact of mean level of BP, linear changes over the interdialytic interval, and oscillatory changes in BP and its relationship with antihypertensive drug use. Neither a straight-line change model nor the cosinor model adequately described the BP variability in 12,750 BP measurements from 136 chronic stable hemodialysis patients. A combination of the 2 models that allowed for the oscillatory rhythmic pattern in BP variation to have an upward trend in the interdialytic period most accurately described the data. Time elapsed since the end of dialysis demonstrated a better model fit compared with the less meaningful clock time. More antihypertensive medication use was associated with increasing mean systolic, diastolic, and pulse pressure. Although the rate of change was blunted with increasing antihypertensive drug use, the impact on oscillatory change was U-shaped for systolic BP, direct for diastolic BP, and inverse for pulse pressure. A trended cosinor model better describes the change in BP in the interdialytic interval in hemodialysis patients, especially when time elapsed is measured from the end of dialysis. Antihypertensive drugs, though associated with higher average BP, are associated with blunted rate of change in BP over time.
More Related Videos
06:38Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats
Published on: March 11, 2016
09:05Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
Published on: January 30, 2015
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Hemodialysis II: Procedure and Complications
Hemodialysis I: Introduction
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Hemodialysis III: Nursing Management
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: