Amiloride-sensitive sodium channels on the parietal human peritoneum: evidence by ussing-type chamber experiments
Ioannis Stefanidis1, Vassilios Liakopoulos, Panagiota Kourti
1Department of Nephrology , School of Medicine, University of Thessaly, Greece.
Abstract:
The mesothelium is part of the peritoneal water and ion transport barrier essential for peritoneal dialysis (PD) treatment and has a central role in the pathogenesis of peritoneal fibrosis and ultrafiltration failure observed in many PD patients. We investigated the effect of amiloride on the transmesothelial electrical resistance (RTM) of isolated parietal human peritoneum. Intact sheets were obtained from seven patients (three men, four women; mean age, 64 +/- 8 years). Fourteen peritoneal planar sheets were transferred to the laboratory in oxygenated Krebs-Ringer bicarbonate solution at 4 degrees C within 30 minutes after removal and mounted in an Ussing-type chamber. Amiloride (10(-3) mol/L) added apically (n = 8) caused a rapid rise of the RTM to 24.15 +/- 0.76 [OMEGA]H cm2 and a subsequent value persistence (p < 0.05); added basolaterally (n = 6), it increased the RTM to 22.66 +/- 0.59 [OMEGA]H cm2 within 1 minute, which persisted throughout the experiment. RTM was measured before and serially for 30 minutes after addition of amiloride. Control RTM was 20.29 +/- 0.86 [OMEGA]H cm2. These results indicate a rapid inhibitory effect of amiloride on the ionic permeability of parietal human peritoneum. The increase in the RTM observed after addition of amiloride clearly indicates the existence of amiloride-sensitive sodium channels on the human parietal peritoneal membrane, which may play some role in the ultrafiltration process and sodium removal during PD.
More Related Videos
08:56Demonstration of Proteolytic Activation of the Epithelial Sodium Channel (ENaC) by Combining Current Measurements with Detection of Cleavage Fragments
Published on: July 5, 2014
11:02Exploring Arterial Smooth Muscle Kv7 Potassium Channel Function using Patch Clamp Electrophysiology and Pressure Myography
Published on: September 14, 2012
Related Concept Videos
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Mechanically-gated Ion Channels
