Early in vivo experience with the pediatric Jarvik 2000 heart
Ahmet Kilic1, Timothy D C Nolan, Tieluo Li
1Department of Surgery, University of Maryland, Baltimore, MD 21201, USA.
Abstract:
The need for smaller, more efficient ventricular assist devices that can be used in a more chronic setting have led to exploration of mechanical circulatory support in the pediatric population. The pediatric Jarvik 2000 heart (child size), under development, was implanted in six juvenile sheep and studied for both acute fit and chronic performance evaluation. Daily hemodynamic measurements of cardiac output and pump output at varying pump speeds were taken. In addition, plasma free hemoglobin, lactic acid dehydrogenase, and platelet activation from blood samples were determined at baseline, after implantation, and twice a week thereafter. The measured flow through the outflow graft at increasing speeds from 10,000 rpm to 14,000 rpm with an increment of 1,000 rpm were 1.47 +/- 0.43, 1.89 +/- 0.52, 2.36 +/- 0.61, 2.80 +/- 0.73, and 3.11 +/- 0.86 (L/min). The baseline plasma free hemoglobin was 11.95 +/- 4.76 (mg/dL), with subsequent mean values being <30 mg/dL at postimplantation and weekly postimplantation measurements. Both lactic acid dehydrogenase and platelet activation showed an acute increase within the first week after implantation with subsequent return to baseline by 2 weeks after surgery. Our initial animal in vivo experience with the pediatric Jarvik 2000 heart shows that a small axial flow pump can provide partial to nearly complete circulatory support with minimal adverse effects on blood components.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiac Catheterization III: Left Heart Catheterization
Development of the Heart
As the embryo undergoes lateral folding, these paired tubes approach each other, merging into a single primitive heart tube by...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...