Related Experiment Video
Updated: Jul 14, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Diagnostic accuracy of image postprocessing methods for the detection of coronary artery stenoses by using
Maros Ferencik1, Dieter Ropers, Suhny Abbara
1Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
Purpose:
To retrospectively evaluate the diagnostic accuracy of multidetector computed tomography (CT) coronary angiography for detection of hemodynamically significant (>or=50%) stenoses by using various image postprocessing methods, with conventional coronary angiography as the reference standard.
Materials And Methods:
The analysis used data from previous studies, use of which had been approved by the Institutional Review Board. Sixteen-section multidetector CT data sets for 40 patients (30 men, 10 women; mean age 56 years +/- 8; mean heart rate, 61 beats per minute +/- 6) were evaluated. Six independent investigators evaluated the data sets for the presence of stenoses with diameter reduction of 50% or more, by using either exclusively transverse images, free oblique multiplanar reconstructions (MPRs), free oblique maximum intensity projections (MIPs, 5 mm thick), prerendered curved MPRs, prerendered curved MIPs, or prerendered three-dimensional volume rendered reconstructions (VRTs). Evaluation results were compared with conventional coronary angiography for each artery in a blinded fashion (chi(2) test).
Results:
Overall, 35 coronary artery stenoses were present. Percentage of evaluable arteries and accuracy for detecting stenosis (percentages of accurately classified arteries were, respectively, 99% and 88% for transverse, 99% and 91% for oblique MPR, 94% and 86% for oblique MIP, 94% and 83% for curved MIP, 93% and 81% for curved MPR, and 91% and 73% for VRT). Accuracy was significantly higher for oblique MPR than for curved MPR (P=.01), curved MIP (P=.03), and VRT (P<.001).
Conclusion:
The evaluation of multidetector CT coronary angiography with interactive image display methods, especially interactive oblique MPRs, permits higher diagnostic accuracy than evaluation of prerendered images (curved MPR, curved MIP, or VRT images).
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System IV: CMRI