Related Experiment Video
Updated: Jul 14, 2026

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Contrast-to-noise ratio (CNR) as a quality parameter in fMRI
Alexander Geissler1, Andreas Gartus, Thomas Foki
1Clinical fMRI Study Group, Departments of Neurology, Neurosurgery, and Radiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
Purpose:
To evaluate the impact of data quality on the localization of brain activation in functional magnetic resonance imaging (fMRI) and to explore whether the temporal contrast-to-noise-ratio (CNR) provides a quantitative parameter to estimate fMRI quality.
Materials And Methods:
We investigated two methods for defining the CNR by comparing them on a single-run, single session, as well as on a group-wise basis. The CNRs of healthy subjects and a group of patients with brain lesions were calculated using two different strategies: one based on a general linear model (GLM) analysis (CNR_SPM), and one that acts as an adaptive low-pass filter and assumes that the high-frequency components contain the temporal noise (CNR_SG). Runs with low CNR were identified as outliers using a common exclusion criterion (2 x standard deviation (SD)).
Results:
The results of the two CNR methods are highly correlated. Both between and within subjects and patients the CNR showed quite large variations, but the average CNR did not differ between a group of healthy subjects and a patient group. In total, seven of 213 runs (3.3% of all runs) had to be excluded when CNR_SG was used, and 14 of 213 (6.6%) runs had to be excluded when CNR_SPM was used.
Conclusion:
Calculating the CNR using an adaptive low-pass filter gives similar results to a GLM-based approach and could be advantageous for cases in which the hemodynamic response function (HRF) differs significantly from common assumptions. The CNR can be used to identify and exclude runs with suboptimal CNR, and to identify sessions with insufficient data quality. The CNR may serve as a quantitative and intuitive parameter to assess the performance and quality of clinical fMRI investigations, including information on both functional performance (contrast) and data quality (noise caused by the system and physiology).
More Related Videos
05:14Standardized Data Acquisition for Neuromelanin-Sensitive Magnetic Resonance Imaging of the Substantia Nigra
Published on: September 8, 2021
08:33A Randomized, Sham-Controlled Trial of Cranial Electrical Stimulation for Fibromyalgia Pain and Physical Function, Using Brain Imaging Biomarkers
Published on: January 5, 2024
Related Concept Videos
Magnetic Resonance Imaging
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Imaging Studies for Cardiovascular System IV: CMRI