Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
First Derivative Test: Problem Solving01:25

First Derivative Test: Problem Solving

Imagine an asset price that crashes to a low point, rebounds sharply as bargain-hunters step in, and then gradually declines. Such behavior can be modeled with a smooth function whose turning points represent locally overvalued and undervalued regions. A convenient example that captures rebound followed by decay is:The high and low points of this curve are identified using the first derivative test, which determines where the function changes from increasing to decreasing or vice versa. To...
The Power Flow Problem and Solution01:26

The Power Flow Problem and Solution

Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk​, phase angle δk​, real power Pk​, and reactive power Qk​. Two of these four variables are inputs, while the power flow program computes the...
Reclosers and Fuses01:26

Reclosers and Fuses

Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Building a value model for population health management.

Healthcare financial management : journal of the Healthcare Financial Management Association·2018
Same author

Patient access innovations: integrating patients within the system of care.

Healthcare financial management : journal of the Healthcare Financial Management Association·2016
Same author

Using business intelligence to reduce the cost of care.

Healthcare financial management : journal of the Healthcare Financial Management Association·2014
Same author

Technology spending and accountable care. CEO's job is to help find a viable path.

Healthcare executive·2012
Same author

Translating accountable care goals into IT action: guidance on strategies, systems, priorities, and pitfalls for hospital CIOs.

Healthcare informatics : the business magazine for information and communication systems·2011
Same author

Two tools for keeping physicians informed and involved.

Healthcare financial management : journal of the Healthcare Financial Management Association·2008

Related Experiment Video

Updated: Jul 14, 2026

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
13:07

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression

Published on: January 15, 2022

Fixing the five 'failure points' that short-circuit cash flow. Case study

Daniel J Marino1

  • 1Health Directions LLC, Lockport, Ill, USA. dmarino@healthdirections.com

MGMA Connexion
|May 25, 2007
PubMed
Summary

No abstract available in PubMed .

Related Experiment Videos

Last Updated: Jul 14, 2026

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
13:07

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression

Published on: January 15, 2022