A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
A practical method of measuring glomerular filtration rate by iohexol clearance using dried capillary blood spots
Marion M Mafham1, Ioana Niculescu-Duvaz, Jeffrey Barron
1Renal Studies Group, Clinical Trial Service Unit, Old Road Campus, Oxford, UK. mmafham@yahoo.co.uk
Background:
Exogenous tracer-based methods of measuring glomerular filtration rate (GFR) are difficult to perform, whilst creatinine-based estimation formulae are inaccurate.
Methods:
We assessed a new technique of measuring iohexol clearance using timed dried capillary blood spots. A reference GFR was measured in 81 subjects (GFR 15-124 ml/min/1.73 m(2)) by iohexol clearance using three venous samples (2, 3 and 4 h after an intravenous bolus). GFR was estimated by six test methods; iohexol clearance using (i) 3 blood spots (2, 3, 4 h); (ii) 2 blood spots (2, 4 h) and (iii) 1 blood spot (4 h); (iv) the Modification of Diet in Renal Disease (MDRD) formula; (v) the Cockcroft-Gault formula, and (vi) a formula estimating GFR from serum cystatin C concentration. For each test method the bias and precision were calculated as the mean and standard deviation (SD) of the 'GFR differences' (test method GFR - reference GFR).
Results:
The limits of agreement (bias +/-1.96 x SD; in ml/min/1.73 m(2)) were: (i) 1.1 +/- 15.1 for 3-spot iohexol clearance; (ii) 0.6 +/- 14.9 for 2-spot iohexol clearance; (iii) 4.5 +/- 21.2 for 1-spot iohexol clearance; (iv) -15.7 +/- 33.3 for the MDRD formula; (v) -9.6 +/- 32.9 for the Cockcroft-Gault formula, and (vi) -12.1 +/- 31.7 for the Cystatin C formula. The accuracy of all six test methods was similar among individuals with GFR <60 ml/min/ 1.73 m(2); however, in individuals with GFR > or =60 ml/min/ 1.73 m(2), the MDRD, Cockcroft-Gault and Cystatin C formulae were all imprecise and systematically underestimated GFR.
Conclusions:
Blood spot iohexol clearance provides a potentially practical method of estimating GFR accurately in large-scale epidemiological studies especially among individuals without established chronic kidney disease.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles.