Related Experiment Video
Updated: Jul 14, 2026

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Biologically variable ventilation improves gas exchange and respiratory mechanics in a model of severe bronchospasm
W Alan C Mutch1, Timothy G Buchman, Linda G Girling
1Department of Anesthesia, University of Manitoba. amutch@cc.umanitoba.ca
Objective:
Mechanical ventilation can be lifesaving for status asthmaticus, but how best to accomplish mechanical ventilation is unclear. Biologically variable ventilation (mechanical ventilation that emulates healthy variation) and conventional control mode ventilation (monotonously regular) were compared in an animal model of bronchospasm to determine which approach yields better gas exchange and respiratory mechanics.
Design:
A randomized prospective trial of biologically variable ventilation vs. control mode ventilation in swine.
Setting:
University research laboratory.
Subjects:
Eighteen farm-raised pigs.
Interventions:
Methacholine was administered as a nebulized aerosol to initiate bronchospasm, defined as doubling of peak inspiratory pressure and respiratory system resistance, and then randomized (n = 9 each group) to either continue control mode ventilation or switch to biologically variable ventilation at the same minute ventilation. Over the next 4 hrs, hemodynamics, blood gases, respiratory mechanics, and carbon dioxide expirograms were recorded hourly. At end-experiment, tracheobronchial lavage was undertaken to determine interleukin-6 and -10 concentrations.
Measurements And Main Results:
Measurements of physiologic variables and inflammatory cytokines showed that biologically variable ventilation significantly improved gas exchange, with greater arterial oxygen tensions (p = .006; group x time interaction), lower arterial carbon dioxide tensions (p = .0003; group effect), lower peak inspiratory pressures (p = .0001; group x time), greater static compliance (p = .0001; group x time), greater dynamic compliance (p = .0001; group x time), and lower total respiratory system resistance (p = .028; group x time), compared with conventional ventilation. The appearance of inflammatory cytokines in bronchoalveolar lavage fluid (interleukin-6 and -10) was not affected by mode of ventilation.
Conclusions:
In this experimental model, biologically variable ventilation was superior to control mode ventilation in terms of gas exchange and respiratory mechanics during severe bronchospasm.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...